About the Rainbird 100DVMB
The Rain Bird 100DVMB is a 1" 24V Electric (Male x Barb) Control Valve. It features a double-filtered pilot-flow design for long-lasting reliability, a balanced-pressure diaphragm, external-bleed to manually flush the system of dirt and debris during installation and system start-up. It also features an internal bleed for spray-free manual operation, energy-efficient low-power encapsulated solenoid with a captured plunger, and a 90-mesh solenoid filter.
|
Product Details
Manufacturer: |
Rainbird |
Product: |
Electric Valve |
Sprinkler Valve Features: |
Globe Valve/ Angle Valve |
Voltage: |
24V |
Pressure Rating: |
15 PSI |
Mpn # |
100DVMB |
Dimensions |
0 " X
0 " X
0 "
|
Weight |
1.02 lbs.
|
|
Product Features
- 0.30 A (7.2 VA) inrush current; 0.23 A (5.5 VA) holding current
- 24 VAC 50/60 Hz (cycles per second) solenoid power requirement:
- 3/4" (20/27) and 1" (26/34) standard in-line configuration.
- Accepts latching solenoid for use with Rain Bird battery-operated controllers.
- Ambient air temperature: Up to 125 Degrees F (52 Degrees C)
- Available as: 3/4" (20/27) and 1" (26/34) standard in-line configuration. 1" (26/34) Slip-by-Slip (SS) configuration for low cost, solvent-weld installations. 1" (26/34) Angle (A) configurations for flexible installations especially when submains are deep. 1" (26/34) Male-by-Male (MM) thread configuration for quick and easy manifolding. 1" (26/34) Male-by-Barb (MB) and 1" Male-by-1.25" Barb male thread inlet by barb outlet configuration for installation with poly pipe.
- Balanced-pressure diaphragm for long life.
- Buna-N diaphragm with self-cleaning 90 mesh (200 micron) pilot water filter and captive spring.
- Double-filtered pilot-flow design for maximum reliability.
- Energy-efficient, low-power encapsulated solenoid with captured plunger and 90-mesh (200 micron) solenoid filter.
- External bleed to manually flush system of dirt and debris during installation and system start-up.
- 075-DV Flow: 0.2 to 22 GPM (0,05 to 5,0 m3/h; 0,01 to 1,39 l/s). For flows below 3 GPM (0,75 m3/h; 0,21 l/s) or any Xerigation application, use RBY-075-200MX Filter installed upstream.
- Height (Angle): 5 1/2" (14 cm)
- Height: 4 1/2" (11,4 cm)
- Internal bleed for spray-free manual operation.
- Length (Angle): 3 3/4" (9,5 cm)
- Length (MB): 5 3/4" (14,6 cm)
- Length (MM): 5 3/8" (13,6 cm)
- Length: 4 3/8" (11,1 cm)
- Operates in low-flow and Xerigation applications when the RBY filter is installed upstream.
- Pressure: 15 to 150 psi (1,0 to 10,4 bar)
- Solenoid coil resistance: 38 Ohms
- 1" (26/34) Angle (A) configurations for flexible installations especially when submains are deep.
- Temperature: Up to 110 Degrees F (43 Degrees C)
- Unique, easy-to-turn patented pressure assisted flow control mechanism (DVF models only).
- Width: 3 1/3" (8,4 cm)
- 1" (26/34) Male-by-Barb (MB) and 1" Male-by-1.25" Barb male thread inlet by barb outlet configuration for installation with poly pipe.
- 1" (26/34) Male-by-Male (MM) thread configuration for quick and easy manifolding.
- 1" (26/34) Slip-by-Slip (SS) configuration for low cost, solvent-weld installations.
- 1.25" (3,2 cm) stainless steel phillips head screws.
- 100-DV Flow): 0.2 to 40 GPM (0,05 to 9,08 m3/h; 0,01 to 2,52 l/s). For flows below 3 GPM (0,75 m3/h; 0,21 l/s) or any Xerigation application, use RBY-100-200MX Filter installed upstream.
- 100-DVF Flow (non-union): 0.2 to 40 gpm (0,75 m3/h; 0,21 l/s); for flows below 3 gpm or any Xerigation application, use RBY-100-200MX Filter installed upstream.
|