About the Honeywell Direct Spark Ignition Control Module - S87J1034

The Honeywell S87J1034 is a direct spark ignition control module that uses a single electrode for spark ignition and flame sensing. This module is suitable for use with any gas control designed for Direct Spark Ignition (DSI) application that is rated at 2.0 A or less. It generates a high voltage for spark ignition, controls the gas valve, and monitors the main burner flame. And also, this product includes a 30-second (minimum) delay for use with system prepurge.

Honeywell has a long history of providing heating and cooling units, dating back to 1885. Here at PlumbersStock, we proudly offer a large selection of Honeywell items. PlumbersStock guarantees that you have access to the highest quality products and resources at very affordable prices.

Manufacturer: Honeywell
Product: Controller
Style: Parts
Room: Utility Room
Mpn # S87J1034
Weight 1.30 lbs.
  • Direct spark ignition control module for gas-fired furnaces, boilers, and heating appliances
  • Uses a single electrode for spark ignition and flame sensing
  • Ideal for use with any gas control designed for DSI application that is rated at 2.0 A or less
  • Includes an alarm circuit and 30-second (minimum) delay for use with system prepurge
  • Controls the gas valve, monitors the main burner flame, and generates a high voltage for spark ignition
  • Valve required: Any DSI valve rated up to 2.0 A maximum
  • Spark igniter / Flame sensor: Q347B (single electrode for spark ignition and flame sensing)
  • Voltage and Frequency: 25 Vac, 60 Hz
  • Current Rating: 0.2 A at 25 Vac
  • Valve Contacts: 2.0 A at 25 Vac
  • Flame failure reignition time: 0.8 sec maximum